0

Heat Seal & Hot Tack Tester

Heat Seal & Hot Tack Tester
Heat Seal & Hot Tack Tester
Price And Quantity
  • Set/Sets
  • 1
  • Set/Sets
  • 2000.00 - 20000.00 USD ($)
    Product Specifications
    • 220VAC 50Hz / 120VAC 60Hz
    • 3
    • 0.05 MPa~0.7 MPa mpa
    • Room temperature~250 °C Celsius (oC)
    • 68kg Kilograms (kg)
    • 200mm/min, 250mm/min, 300mm/min
    • 15 mm or 25 mm or 25.4 mm Millimeter (mm)
    • 78.5 mm
      Product Description

      Heat Seal & Hot Tack Tester

      i-Thermotek 2400 Heat Seal & Hot Tack Tester is utilized for hot tack test of complex films, plastic films, and added packaging resources as well it can be applied to grade the heat seal forte of the test example fast and exactly within a specified time after heating and sealing measures. Also, the closing confines of the substrate constituents of supple compound film, coated paper, plastic film, or extra complex flicks can be usual with certain sealing compression, sealing rapidity and at three unrelated sealing temperatures in a single examination. Meanwhile, thermo-stability, the melting point, variability or width of the constituents are diverse, they display great alteration in the closing limits. With i-Thermotek 2400 Heat Seal & Hot Tack Tester, the optimal sealing limitations can be gotten rapidly and accurately.

      Principle

      Heat Seal Test : The compressed air is presented into the gas cylinder with convinced pressure. The implanted arrangement can govern the swapping of the solenoid valve. The course of the pressure given will be altered so that the sealing jaws can transfer downward and upward. The packaging substances can be sealed at specific sealing force and sealing temperature within the abide time.

      Hot Tack Test : Clamp the two ends of the sample in left model grips and right model grips (with load cell) correspondingly. Then pull the sample to the hot tack examination area. Following the hot tack test, the lashing mechanism will pull the right and left sample grips in reverse orders and the load cell can notice the electric indication and then the hot tack forte, tensile strength and peel strength can be examined or calculated.

      Heat Seal Strength : Clamp one end of the sample in right model grips and the other end in the holding seat. The driving device will jerk the right model grips so that it will transfer in the opposite course of the fastening seat. The load cell can notice the electric indication and then the heat seal forte can be planned.

      Standards

      This instrument imitates to multiple parameters i.e. ASTM F2029Note3, ASTM F1921, QB/T2358 (ZBY 28004), ASTM F88Note4, and YBB 00122003.

      Applications :

      This instrument is premeditated to degree the following substances:

      Heat Seal Test

      Heat seal tests of numerous plastic composite films, plastic films, co-extrusion films, paper plastic composite films, aluminum foils, aluminized films, and aluminum plastic complex films

      Hot Tack Test

      Hot tack tests of plastic sheeting, films, and composite films like PP, PET, PE or those complex films for washing powder, instant noodle, and other drugs or food, etc.

      Heat Seal Strength

      Heat seal strength examines of numerous plastic merged films, plastic films, paper plastic complex films, aluminized films, co-extrusion films, aluminum plastic composite films and aluminum foils following heat seal examination

      Features:

      Professional

      • With the help of the digital P.I.D. temperature control arrangement, the preset temperature can be touched in a short period deprived of fluctuations.
      • Extensive range of temperature, heaviness and dwell time can cater to numerous testing necessities.
      • The test can be initialized physically or by pedal switch, which is suitable to function. The anti-scald plan can assure the security of the operator.
      • Three groups of examinations with two separate examples can be achieved every time, which recovers the testing competence.
      • The temperatures of the lower and upper sealing jaws can be measured independently, which can cater to the requirements for dissimilar test conditions.
      • Hot tack test can be achieved, which can cater to the specific necessities of the users.
      • The test outcomes can be estimated with provision of professional software.

      High-end

      • Entrenched computer regulator system offers safer and more consistent data organization as well as test process
      • The system can be simply functioned by a standard examination, keyboard and a mouse, no PC mandatory.
      • The system is prepared with four USB jacks and dual internet jacks for easy output, input, and data transfer.

      Note 1: Three upper sealing jaws are there and one lower sealing jaw is given for heat seal examination. The temperature of these sealing jaws is controlled autonomously. These upper sealing jaws are frenzied sealing jaws when the subordinate sealing jaw is unheated sealing jaw. Thermal sealing jaw can be designated as lower sealing jaw.

      Note 2: There are one motionless sealing jaw and one portable closing jaw for hot tack examination, together of which are heated sealing jaws. The heat of the sealing jaws can be regulated self-reliantly. Unheated sealing jaw can be nominated as motionless sealing jaw.

      Note 3: Two sorts of power supply can be chosen.

      Technical Specifications


      Heat Seal Test

      Sealing Temperature

      Room temperature~250oC

      Sealing Pressure

      0.05 MPa~0.7 MPa

      Dwell Time

      99.9s

      Resolution

      ±0.1oC

      Accuracy

      ±2oC

      Temperature Gradient

      20oC

      Sealing Area

      55mm-10mm

      Number of Sealing Jaws

      3+1Note1

      Hot Tack Test

      Sealing Temperature

      Room Temperature~250oC

      Resolution

      +0.1oC

      Accuracy

      ±1oC

      Dwell Time (Heat Seal)

      99.9s

      Dwell Time (Hot Tack)

      20s

      Sealing Pressure

      0.05~0.7MPa

      Number of Sealing Jaws

      1-1Note2

      Capacity Range

      0~50N (Optional)

      Test Accuracy

      1% FS

      Resolution

      0.1N

      Specimen Width

      15 mm or 25 mm or 25.4 mm

      Heat Seal Strength

      Capacity Range

      0~50N (Optional)

      Test Accuracy

      1% FS

      Resolution

      0.1N

      Specimen Width

      15 mm or 25 mm or 25.4 mm

      Speed

      200mm/min,250mm/min,300mm/min (Customization is available)

      Stroke

      78.5 mm

      Others

      Gas Supply

      Air (Outside of supply scope)

      Gas Supply Pressure

      0.05~0.7MPa

      Port Size

      6 mm PU Tubing

      Dimension

      500 mm (L) x 580 mm (W) x 575 mm (H)

      Power Supply

      AC220V 50Hz/AC120V 60HzNote3

      Net Weight

      50 kg

      Configurations

      Standard

      Instrument (Including wireless data interface¯, Embedded Software, Standard LCD Monitor, Keyboard, Mouse, Calibration Frame, Pedal Switch, Sample Cutter and Valve tubing Set, Printer

      Optional

      Strip Sample Cutter, Unheated Sealing Jaw, Air Compressor and Desiccant


      Trade Information
      • 10 Per Month
      • 7 Days
      • Veneer Case
      • All India
      • ISO 9001, CE
      Contact Us

      144, Wuyingshan Road, Jinan, Shandong, 250031, China
      Phone :86-531-85068566